ZERAMEX®XT Transfer Closed Tray RB Archives - Emerginnova https://emerginnova.com/description/zeramex-xt-transfer-closed-tray-rb/ Fri, 12 Jul 2024 15:50:05 +0000 en-US hourly 1 https://wordpress.org/?v=6.4.1 https://emerginnova.com/wp-content/uploads/2019/04/fav-100x100.png ZERAMEX®XT Transfer Closed Tray RB Archives - Emerginnova https://emerginnova.com/description/zeramex-xt-transfer-closed-tray-rb/ 32 32 ZERAMEX®XT Transfer Closed Tray RB – RB36512 https://emerginnova.com/product/zeramex-xt-transfer-closed-tray-rb/?utm_source=rss&utm_medium=rss&utm_campaign=zeramex-xt-transfer-closed-tray-rb https://emerginnova.com/product/zeramex-xt-transfer-closed-tray-rb/#respond Tue, 04 Dec 2018 10:52:06 +0000 https://emerginnova.com/?post_type=product&p=1401 ZERAMEX® XT Transfer Closed Tray RB:

Sleeve height: 7mm
Height incl. screw: 14mm

Material: PEEK-CW30, Aluminum

The post ZERAMEX®XT Transfer Closed Tray RB – RB36512 appeared first on Emerginnova.

]]>
Auxiliary parts Name Dimension material
ZERAMEX-XT-Provisonal-Screw-RB-WB-510x510
ZERAMEX® XT Transfer Closed Tray RB
Sleeve height: 7mm

Height incl. screw: 14mm
PEEK-CW30, Aluminum

TAKING IMPRESSIONS

Closed tray:

Impression Material 1
Impression Material 2
Impression Material 3

1. Positioning: Place the transfer sleeve on the external hexagon under slight pressure while turning until it snaps into the hex head socket, rests securely on the implant shoulder, and can no longer be rotated.

2. Screwing tight: Tighten the
lukewarm locking pin clockwise,
and check the position for a form-fit.
In case of doubt, take an X-ray.

3. Taking an impression:
Prepare the impression with a
closed tray and remove. Unscrew the
locking pin, remove the transfer from the implant, and give the transfer and impression to the dental technician.

Impression Material 4
Impression Material 5
Impression material 6

4. Connecting: Place the transfer sleeve on the external hexagon under slight pressure while turning it until it snaps into the hex head socket of the implant replica, rests securely on the shoulder, and can no longer be rotated. Screw the lukewarm locking pin tight clockwise.

5. Reposition and create a model: Reposition the transfer in the impression with the screwed-on implant replica and ensure that the seat is secure. Create a master model.

6. Restoration: Select a secondary component depending on the prosthetic requirements and the related procedure. Straight and angular screw-retained abutments (more on page 29) and straight and angular cemented abutments and Locator® (more on page 37) are available.

Open tray:

Impression Material 1
Impression Material 2
Impression Material 3

1. Positioning: Place the transfer sleeve on the conditions. external hexagon under slight pressure while turning until it snaps into the hex head socket, rests securely on the implant shoulder, and can no longer be rotated.

2. Screwing tight: Screw the transfer sleeve hand-tight. Tighten the lukewarm locking pin clockwise, and check the position for a form-fit. In case of doubt, take an X-ray.

3. Taking an impression: Create the impression with an open tray. Unscrew and remove the locking pin. Remove the impression, and give it to the dental technician with the locking pin.

Impression Material 4
Impression Material 5
Impression Material 6

4. Connecting: Place the implant replica on the external hexagon under slight pressure while turning until it snaps into the transfer sleeve, rests securely on the shoulder, and can no longer be rotated. Tighten the locking pin clockwise under lukewarm conditions.

5. Creating the model: Reposition the transfer with the screwed-on implant replica, and make sure that the seat is secure. Create a master model. Remove the locking pin before removing the impression.

6. Restoration: Select a secondary component depending on the prosthetic needs and the preferred procedure. Straight and angular screw-retained abutments (more on page 29) and straight and angular cemented abutments and Locator® (more on page 37) are available.

IMPRESSION TAKING

Taking impressions Art no. name dimension Link

ZERAMEX® XT Transfer Open Tray RB

RB36510
ZERAMEX® XT Transfer Open Tray RB
Sleeve height: 11mm

Height incl. screw: 20mm

ZERAMEX® XT Transfer Closed Tray RB

RB36512
ZERAMEX® XT Transfer Closed Tray RB
Sleeve height: 7mm

Height incl. screw: 14mm
RB36513
ZERAMEX® XT Transfer Closed Tray, long RB
Sleeve height: 11mm

Height incl. screw: 18mm

ZERAMEX® XT Scanbody RB (incl. Screw)

RB36514
ZERAMEX® XT Scanbody RB (incl. Screw)
Height: 10mm
Auxiliary parts Art no. name dimension Link

ZERAMEX®XT Implant-Replica RB

RB36520
ZERAMEX® XT Implant Replica RB
Length: 10mm

ZERAMEX® XT Provisional Screw RB & WB

RB36550
ZERAMEX® XT Provisional Screw RB & WB
Length: 8.6mm

ZERAMEX®XT LAB Screw RB & WB

RB36553
ZERAMEX® XT Lab Screw RB & WB
Length: 7.4mm

The post ZERAMEX®XT Transfer Closed Tray RB – RB36512 appeared first on Emerginnova.

]]>
https://emerginnova.com/product/zeramex-xt-transfer-closed-tray-rb/feed/ 0